Maldron Hotel

Salford

Description

Redevelopment of a site formerly used as a surface car park into a new 17-storey hotel comprising 188 bedrooms, a bar and restaurant, coffee lounge, state-of-the-art meeting rooms, and gym facilities.

Innovation Fire Engineering provided our client with solutions to a wide range of fire safety issues such as justifying the omission of sprinklers, complying with external fire spread requirements for close boundary distances, justifying the ventilation requirements for the fire-fighting shaft, and providing compliant solutions for an open-accommodation staircase through compartment floors.

Our services included a Fire Options Document, a Detailed Fire Strategy, Computational Fluid Dynamics Analysis, and On-going Support.